A single dust particle can impair the functionality of a microchip, while microbial contamination can compromise the safety of a pharmaceutical product. Sensitive manufacturing environments therefore require particularly stringent cleanliness standards.
But what defines a cleanroom, and how does the right cleanroom clothing contribute to contamination control?
What Is a Cleanroom?
A cleanroom is a controlled working environment in which the concentration of airborne particles is limited to a defined level. Specialised filtration systems, controlled airflow, and regulated access procedures reduce the introduction and spread of contaminants.
Cleanrooms are primarily used in the pharmaceutical industry, microelectronics, medical technology, biotechnology, and semiconductor manufacturing.
Cleanroom Classification According to ISO 14644
DIN EN ISO 14644-1 classifies cleanrooms into nine cleanliness classes based on the permissible concentration of airborne particles. The lower the ISO class, the more stringent the air cleanliness requirements.
Cleanroom Class | Max. Particles ≥ 0.5 µm per m³ |
ISO3 | 35 |
ISO4 | 352 |
ISO5 | 3.520 |
ISO6 | 35.200 |
ISO7 | 352.000 |
ISO8 | 3.520.000 |
ISO9 | 35.200.000 |
At this particle size, an ISO Class 5 cleanroom may therefore have only one thousandth of the permissible particle concentration of an ISO Class 8 cleanroom.
The manufacture of sterile medicinal products is also subject to the requirements of Annex 1 of the EU GMP Guidelines. It distinguishes between cleanroom grades A to D and addresses both particulate and microbiological contamination.
Humans as a Source of Contamination
Skin flakes, hair, textile fibres and particles released through breathing make humans a major source of contamination in cleanrooms. Even everyday movements can contribute to the release and spread of particles.
Suitable cleanroom clothing forms a barrier between personnel and their working environment. It is designed to minimise both the release of particles from the human body and the introduction of contaminants from the clothing itself.

What Requirements Must Cleanroom Clothing Meet?
Depending on the cleanroom class and the specific production process, the following properties are particularly relevant:
Low Particle Release: Low-linting, low-particle-shedding materials minimise additional contamination.
Barrier Performance: Suitable materials and seam constructions reduce the release of particles from the human body.
Antistatic Properties: Where suitable, these help control electrostatic charge build-up.
Sterility: Sterile cleanroom clothing is required for certain processes, particularly in aseptic pharmaceutical manufacturing.
The key is how all garment components work together – from the hood, mask, coverall and protective gloves to the shoe covers.
Putting Cleanroom Clothing to the Test
The Helmke Drum Test in accordance with IEST-RP-CC003.5 is one of the methods used to determine particle release from cleanroom clothing. During the test, the garment is tumbled in a rotating drum, and the number of airborne particles released is measured.
DACH Schutzbekleidung uses this test method to assess particle release from its cleanroom clothing.
Discover Our Cleanroom Clothing
Low-particle-shedding materials, tested quality and coordinated garment components: Our cleanroom clothing has been specifically developed for controlled working environments with stringent hygiene and contamination control requirements. Selected products are also available in sterile versions.